Test Code 151 Electrolyte Panel
Additional Codes
ALAB: LYTES
PowerChart: Electrolyte Panel
MA Cerner: Electrolytes
Test Method
MercyOne DBQ : Beckman DxC700AU
Sodium: Ion Exchange
Potassium: Ion Specific Electrode
Chloride: Ag/AgCl Electrode
CO2:Rate of pH Change, CO2 Electrodes
Mercy DV and MQMA: iSTAT
Sodium: Ion Selective Electrode Poteniometry
Potassium: Ion Selective Electrode Poteniometry
Chloride: Ion Selective Electrode Poteniometry
CO2: Ionic Strength Measurement
MA East and West: Roche Cobas 6000
Sodium: Ion-Selective Electrode (ISE) Method
Potassium: Ion-Selective Electrode (ISE) Method
Chloride: Ion-Selective Electrode (ISE) Method
CO2: Enzymatic Rate Method
Specimen Requirement
0.5 mL serum or plasma is required.
Additional Specimen Collection Information
Collect blood in a lithium heparin, green-top or red-top tube. PST and SST (gel tubes) are acceptable. Serum or plasma should be separated from contact with the cells within 2 hours of collection. Specimens not centrifuged within 4 hours of collection may be rejected. Refrigerate the specimen if unable to assay within 8 hours of collection. Hemolyzed specimens are not acceptable. Samples with >3+ lipemia must be cleared prior to analysis.
Performance
Testing is performed Monday through Sunday.
Routine orders: Typically completed within 4 hours after the specimen arrives at the testing site.
Expedite: Typically completed within 1 hour after the specimen arrives at the testing site.
STAT: Typically completed within 30 minutes after the specimen arrives at the testing site.
Reference Values
Sodium: 135-145 meq/L
- Critical Values:
- Low: <120 meq/L
- High: >160 meq/L
Potassium: 3.5-5.0 meq/L
- Critical Values:
- Low: <3.0 meq/L
- High: >6.0 meq/L
Chloride: 100-108 meq/L
CO2: 22-32 meq/L
- Critical Values:
- Low: <10 meq/L
- High: >40 meq/L
Anion Gap (calculated): 7-16 meq/L
CPT Code Information
80051 Multitest Laboratory Panel: Electrolyte Panel
Useful For
See individual tests.
LOINC Code Information
24326-1 Electrolyte 1998 Panel-Serum or Plasma