Test Code 324 Cell Count Miscellaneous Fluid
Additional Codes
ALAB: CELLCTMF
PowerChart: Cell Count with Differential Body Fluid
MA Cerner: Fluid Total Cell Count.
Test Method
Sysmex XN System:
- WBC: Impedance counting
- RBC: Impedance counting
- WBC Differential: Flow cytometry
Alternate Method: Hemacytometer Counting Chamber and Microscopy
Specimen Requirement
1 mL of body fluid is required.
Additional Specimen Collection Information
Transfer 1 mL of body fluid from the collection syringe to an EDTA purple-top tube. Clotted specimens are not acceptable for cell counts. If the analysis is delayed refrigerate for up to 24 hours.
Wright Stain or Gram Stain: Perform a "Cytospin" on the sample as soon as possible. Do not use anticoagulant and do not refrigerate the sample.
Performance
Testing is performed Monday through Sunday.
Routine orders: Typically completed within 4 hours after the specimen arrives at the testing site.
Expedite orders: Typically completed within 2 hours after the specimen arrives at the testing site.
STAT orders: Typically completed within 1.5 hours after the specimen arrives at the testing site.
Reference Values
Reference values for miscellaneous fluid cell counts are not established. Results are subject to interpretation by the clinician.
CPT Code Information
89051 Other Pathology Services: Cell Count, miscellaneous body fluids, except blood; with differential count
Useful For
These counts are used as clinical guides in the diagnosis and/or monitoring of diseases processes.
LOINC Code Information
57845-0 Leukocytes [#/Volume] In Body Fluid By Automated Count